What Does Reverse Osmosis Remove?
Reverse osmosis can reduce lead, arsenic and nitrate in drinking water, although removal depends on the system and its maintenance.
It can also reduce certain other dissolved substances and particles, but it does not guarantee that every contaminant is removed. Understanding your source water and checking a system’s specific claims are essential parts of managing drinking water quality.
Which 9 types of contaminants can reverse osmosis remove?
Reverse osmosis pushes water through a membrane that separates much of the dissolved material from the water collected for drinking. A complete system may also include filters that remove substances before or after water reaches the membrane.
1. Lead and copper
Reverse osmosis membranes can reduce dissolved lead and copper, which may enter water from plumbing. The membrane restricts the passage of these dissolved metals, directing much of them into the system’s reject water rather than the drinking-water outlet.
Choose a system with an independently verified reduction claim for the metal you need to address. If plumbing is the concern, test water at the tap where it is used and follow the laboratory’s sampling instructions. Replace filters and membranes according to the manufacturer’s schedule.
Evidence: The separation principle is established, but the studies cited here do not include a lead- or copper-specific household trial. A product claim is more informative than assuming every reverse osmosis unit performs equally well.
2. Arsenic
Reverse osmosis can reduce dissolved arsenic, but the result depends on the form of arsenic in the water and the system’s condition. Some forms are harder to remove than others, so a device’s general ability to reduce dissolved substances is not enough to establish its arsenic performance.
Test the source water and choose a system with a relevant arsenic-reduction claim. If arsenic is present, ask a water-treatment professional or laboratory whether the water should be tested for its different forms and whether pretreatment is needed. Retest treated water after installation and periodically thereafter.
Evidence: A survey of Nevada homes using reverse osmosis found that arsenic generally decreased, but treated concentrations remained above 0.010 mg/L in 10 of the 19 homes with these devices. That is the EPA limit for public drinking water, not a guarantee that any home system meets it. The survey demonstrates why follow-up testing matters.
3. Nitrate
Reverse osmosis can reduce nitrate, a dissolved contaminant that can enter groundwater from sources such as fertilizer and septic systems. The membrane separates much of the nitrate from the water collected for drinking, but the amount removed varies by system and operating conditions.
For a private well, test specifically for nitrate and select a system with a verified nitrate-reduction claim. Retest the treated water rather than relying on taste: nitrate may not be noticeable. The EPA public-water limit is 10 mg/L when nitrate is reported as nitrogen, so check how the laboratory reports the result.
Evidence: Nitrate reduction is a recognized reverse osmosis application, but no nitrate-specific household study is cited here. Nitrate is especially concerning for infants. If water is high in nitrate or its safety is uncertain, use known-safe water for infant formula and ask a health professional for advice; boiling does not remove nitrate.
4. Fluoride
Reverse osmosis can reduce fluoride because the membrane restricts the passage of dissolved fluoride in water. Reduction is not necessarily complete, and performance depends on the particular membrane and system.
If fluoride reduction is your goal, look for an independently verified fluoride claim and check treated water when an accurate result is important. If your household relies on community fluoridation, consider that reverse osmosis can also reduce the fluoride that was intentionally added to the water.
Evidence: Fluoride reduction is an established application of reverse osmosis, but the studies cited here do not measure it in home systems. A clinician or dentist can help families with questions about fluoride needs, particularly for children.
5. Dissolved salts and hardness minerals
Reverse osmosis reduces many dissolved salts and minerals, including sodium, chloride, calcium and magnesium. Removing calcium and magnesium can make the treated drinking water less hard. Reduction of these substances is also why a treated sample often has a lower total dissolved solids, or TDS, reading.
Use a system rated for the substances of concern, especially if the source water is unusually salty or hard. Hardness can contribute to membrane scaling, so check whether the manufacturer recommends pretreatment for your water. A drinking-water unit treats the water that passes through it; it does not necessarily soften water throughout the home.
Evidence: Dissolved-salt separation is a core reverse osmosis function. An industrial wastewater experiment also demonstrated substantial chromium and sulfate separation, but its simulated electroplating conditions do not establish the performance of a household unit.
6. Some PFAS
Reverse osmosis can reduce certain per- and polyfluoroalkyl substances, or PFAS. These chemicals differ from one another, however, so reduction of one PFAS should not be assumed to mean equal reduction of all others.
If PFAS are a concern, test the source water where appropriate and choose a system with an independently verified claim for the specific substances identified. The EPA has set limits for PFOA and PFOS, but a product’s certification and a treated-water test are the practical ways to assess a particular installation.
Evidence: The studies cited here do not include a PFAS-specific household trial. Reverse osmosis can be an appropriate reduction method, but its effectiveness depends on the chemicals present, the system and maintenance. Do not judge PFAS removal by taste or a TDS reading.
7. Some microorganisms
An intact reverse osmosis membrane can restrict bacteria and other particles, but a membrane alone is not a complete guarantee against microorganisms. Viruses are smaller, and performance can be affected by damaged components, poor seals or contamination after filtration, including in a storage tank.
Use the system as directed and maintain its filters and storage components. For water known or suspected to be microbiologically unsafe, use a treatment approach specifically designed for that risk. During a boil-water advisory, follow local authorities’ instructions rather than assuming a household reverse osmosis unit makes the water safe.
Evidence: Physical filtration supports removal of many microorganisms, but the studies cited here do not establish pathogen removal by a particular home system. Look for pathogen-specific performance claims when that protection is needed.
8. Some pesticides and other organic chemicals
Reverse osmosis can reduce some organic chemicals, including certain pesticides and industrial contaminants. Removal varies with the chemical and membrane: smaller molecules or substances with different chemical properties may pass through more readily. A carbon filter in the system can also contribute to reduction of some organic chemicals.
Identify the chemical you need to address and check for a product claim specific to it. A general claim about improving taste, or a low TDS reading, does not establish removal of a pesticide or industrial chemical.
Evidence: A study of chlorophenol rejection showed that membrane performance depends on operating conditions. In a separate membrane-development study, researchers improved removal of the challenging chemical NDMA using a modified prototype. Neither result means an ordinary home unit removes every organic chemical.
9. Chlorine and, with the right filter, chloramine
Complete reverse osmosis systems often reduce chlorine using a carbon prefilter rather than relying on the membrane itself. This stage can improve taste and odor and help protect certain membranes from chlorine damage. Chloramine is a different disinfectant and may require a filter specifically designed and tested for it.
Check whether your water supplier uses chlorine or chloramine, then look for the corresponding reduction claim. Replace the prefilter as directed: an exhausted filter may not perform as intended, even when water still flows normally.
Evidence: Carbon filtration is a recognized way to reduce these disinfectants, but the reverse osmosis studies cited here do not establish chlorine or chloramine removal for a specific household product. Claims should apply to the complete system and the disinfectant in your water.
How can you check whether reverse osmosis is working?
Start with a water test or your public water supplier’s report to identify concerns. A supplier’s report describes the distribution system, but it may not capture metals introduced by plumbing at your tap. Private well owners are responsible for arranging their own testing.
Match the system’s independently verified claims to the contaminants you need to reduce; NSF/ANSI 58 is one standard used for reverse osmosis systems. Check the individual claims rather than treating a certification mark as proof that every listed contaminant is covered. After installation, use an appropriate laboratory test on treated water when you need to verify reduction of a particular substance.
Keep a record of filter and membrane changes, and follow the manufacturer’s maintenance instructions. A TDS meter can help track changes in dissolved material, but it cannot identify lead, nitrate, PFAS or microorganisms, and a low reading does not prove the water is safe.
Frequently asked questions
Is reverse osmosis water the same as distilled water?
No. Reverse osmosis uses a membrane, while distillation involves vaporizing water and condensing the vapor. Both can reduce many dissolved substances, but their results depend on the equipment and contaminant.
Does reverse osmosis produce wastewater?
Yes. A typical system sends water carrying concentrated rejected substances to a drain. The amount varies by system and operating conditions.
Can reverse osmosis water be used for cooking?
Yes, water from a properly maintained system can be used for cooking. If a contaminant is a concern, verify that the system is suitable for it and that the treated water meets your needs.
Sources
- Reverse osmosis filter use and high arsenic levels in private well water. Archives of environmental & occupational health (2006). PubMed 17867571
- A Reverse Osmosis Process to Recover and Recycle Trivalent Chromium from Electroplating Wastewater. Membranes (2022). PubMed 36135873
- High rejection reverse osmosis membrane for removal of N-nitrosamines and their precursors. Water research (2018). PubMed 29268083
- Modeling and optimization of chlorophenol rejection for spiral wound reverse osmosis membrane modules. Chemosphere (2021). PubMed 33360146